Accurate Calibration of CCD-Cameras
Abstract
A basic review of the bundle adjustment with self-calibration is given. The mathematical model, parameter estimation, and quality analysis of calibration and positioning are covered. The calibration procedure, hardware, and testfield of an accuracy investigation with off-the-shelf CCD (charge-coupled device) camera, lens, and frame grabber are described. A relative accuracy in object space of 1 part in 30000 and an accuracy of 1/45 in image space were verified by independent measurements with theodolites.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
Cite
Text
Beyer. "Accurate Calibration of CCD-Cameras." IEEE/CVF Conference on Computer Vision and Pattern Recognition, 1992. doi:10.1109/CVPR.1992.223221Markdown
[Beyer. "Accurate Calibration of CCD-Cameras." IEEE/CVF Conference on Computer Vision and Pattern Recognition, 1992.](https://mlanthology.org/cvpr/1992/beyer1992cvpr-accurate/) doi:10.1109/CVPR.1992.223221BibTeX
@inproceedings{beyer1992cvpr-accurate,
title = {{Accurate Calibration of CCD-Cameras}},
author = {Beyer, Horst A.},
booktitle = {IEEE/CVF Conference on Computer Vision and Pattern Recognition},
year = {1992},
pages = {96-101},
doi = {10.1109/CVPR.1992.223221},
url = {https://mlanthology.org/cvpr/1992/beyer1992cvpr-accurate/}
}